Seven Hills International Limited

 

 - Water Quality Mointoring Systems

 

 

BIOAqua Irrigation Water Quality Monitoring System



 

BIOAqua Irrigation Water Quality Monitoring System is an irrigation water monitoring unit prepared for automating and controlling hydrants in an irrigation system.

It incorporates a solid GSM/GPRS communications system that ensures maximum coverage and minimizes the costs of transmitting guidelines and commands from the control centre.

Structure System

  • BIOAqua Irrigation Water Quality Monitoring System irrigation water monitoring unit.

  • UCR OPC Driver: communication management software. It is the bridge between the control center or SCADA and BIOAqua Irrigation Water Quality Monitoring System equipment.

The main advantage of the system based on GSM / GPRS communication is the simplicity of its architecture since all computers directly communicate with the UCR OPC Driver. This architecture allows data transmission in real or deferred time, as needed and depending on feed-in system.

BIOAqua Irrigation Water Quality Monitoring System – Operation
System Operation:

Smooth Operation of the system ensures

  • Control, acquisition and storage of information of the entire network (consumption, pressure, levels etc.).

  • Double solenoid valves operation management.

  • Control and alarm in case of intrusion, flooding, valves failure etc.

All information sent and received by BIOAqua Irrigation Water Quality Monitoring System equipment is stored by the UCR OPC Driver and can be managed by any control center using standard OPC communications



 


BIOAqua Irrigation Water Quality Monitoring System - System Components
System components

  • Bio Aqua Irrigation water quality monitoring system with remote communication unit
Optional
  • Sensors and probes
  • Control valves
  • Electrical cabinets
  • Sprinklers
  • And other hardware as required based on the specific site conditions

 

 

Unique Characteristics of BIOAqua Irrigation Water Quality Monitoring System
  • Management of 4 hydrants.

  • GSM / GPRS communication.

  • 8 years autonomy .

  • Versatile power system with integrated SLA battery charger.

  • Reading smart meters.

  • Storage capacity of irrigation programs.

  • Hydrant failure alarms.

 

 

 


 

Benefits of BIOAqua Online Dammed Water Quality Analyzer
  • Automatic control of hydrants in an irrigation system

  • Efficient data communication between the system and SCADA / control centre

  • Real time data available at the control centre enables dynamic resource allocation.

  • Instant communication at control centre, in case of intrusion, flooding, valve failure and others .

  • Enable users from remote control centre to control the irrigation system.

 

BIOAqua Irrigation Water Quality Monitoring System - Specifications

 

Temperature Range: -30ºC à +60ºC
Protection Degree: IP66
Communications: Profibus DP, integrated GSM/GPRS Modem,
External Power (Limited power source)
Nominal : 12 Vdc
Tolerance: +7,2 Vdc … +20 Vdc
Maximum current: 0.5 A
Power Solar Panel
Voltage nominal panel: 12 Vdc
Maximum current load: 150 mA
Nominal voltage battery: 12 Vdc
Float Voltage: 13,8 Vdc
Protections: Reverse polarity, overvoltage and temperature compensation
Internal Power (Limited power source)
Batteries: 8 Lithium Batteries (4 groups of 7,2V in parallel)
Power Output (Optional)
Nominal voltage/current: 24 Vdc / 100 mA et 5 Vdc / 50 mA
Activation: Set up activation time to minimize consumption.
Protection: Short circuit
Pulse Inputs
No. Meters: 4
Minimum Pulse: 1 ms
Maximum frequency: 65535 pulses / registration period or 10Hz
Cable Maximum length 100 m
Alarm generation: Set up by overcoming number of pulses
Smart Meters (Optional)
Bus: CZBus (3 hilos, SEL, SDATA, GND)
Frames: A Type
No. Meters: 4
Reading time: 60s
Cable Maximum length 20 m
Digital Inputs
No.Imputs 8
Filtering period: 1… 60 seconds
Alarm generation: Set up by low level
Analog inputs
No.Inputs: 4
Range: 0…25 mA / 0…10 V
Accuracy : 1 %
Alarm generation: Low and/or high level
Protection: Over current and over voltage to 24Vdc
Valve excitation output
No. Outputs: 4
Configuration: 2 / 3 Wires
Nominal : 9 V / 12 V / 24 V, setup configuration
Maximum current: 500 mA / 0.5 sec
Cable Maximum length 100 m
Protection: Short-circuit
Communications:
Modem: GSM / GPRS
RS232C: 19200 bps / No parity / 2 Stop bits
USB : (Optional)

 

BIOAqua Irrigation Water Quality Monitoring System – Software

BIOAquaView, the desktop-based data download application which allows data download, visualization and export in a user-friendly environment. The software allows tracking events such as sampling status or cleanups. BIOAquaView is the perfect complement to your BIOAqua range of products.